Lithium Cell Capacity Grading And Matching Charge Discharge System
A number of DT50W-128 can constitute a testing group to match the needs of mass testing.
Applicable Batteries:
Battery cells of Li-Ion, polymer, Ni-MH, Ni-Cd, etc.
Features:
• Each channel is equipped with a dedicated processor to ensure a perfect level of capacity calculation, timing, voltage and current control.
• All channel is under isolated test, it can directly test the cells of battery pack.
• Independent heat source channel, temperature control and speed regulation fan.
• The LED light indicates the running status, testing status, matching status, alarm status.
• Fully compatibility with the batteries of Li-ion, Polymer, Ni-MH, NiCd, and so on.
• Fully compatible installation with 18650, 26650, 36650, pouch, block batteries.
• The height of the probe is adjustable, ruler scale for easy leveling
• Online test between computer and device, the setting and result is particular and plentiful,
• With the work steps of Constant Current Discharge, Constant Power Discharge, Constant Resistance Discharge, Constant Current Charge, Constant Voltage Charge, Constant Current & Voltage Charge, Internal Resistance Test and Idle, etc.
• Work step automatically switching.
• The charge and discharge parameter can be customized.
• The matching can be processed, the test results can be matched according to the customized standard, and it can mark and display on the device.
• The recording function of the test process
• With 3 Y-axis (voltage, current, capacity) and a time axis curve drawing ability, and data report function.
• The color of the test status bar is customized, which makes it easy to check the test status of all devices when the number of tests is large.
Technical Specification:
Model No.: DT50W-128 | ||
Input Voltage: | AC 220V± 10% 50Hz/60Hz | |
Input Power: | No-load 0.64KW, full load 13.2KW | |
Channel No.: | 128 | |
Voltage
|
Max. Charge Constant Voltage: | 5V |
Min. Discharge Cut-off Voltage: | 1V | |
Tolerance: | 0.02V | |
Current
|
Max. Charge Current: | 10A |
Max. Discharge Current: | 10A | |
Min. Charge Cut-off Current | 0.05A | |
Tolerance: | 0.02A | |
Power | Max. Output Power ( Single Channel ) | 100W |
Data Recording
|
Data Recording Conditions
|
Time interval |
Voltage interval | ||
Current interval | ||
Charge
|
Charge Modes:
|
Constant current charge |
Constant voltage charge | ||
Constant current & voltage charge | ||
Charge Cut-off Conditions: | Voltage, Current, Time, Capacity, -△V | |
Discharge
|
Discharge Modes:
|
Constant current discharge |
Constant power discharge | ||
Constant resistance discharge | ||
Charge Cut-off Conditions: | Voltage, Current, Time, Capacity | |
Cycle
|
Cycle Index: | 1-9999 times |
Cycle Nest | Nestable | |
Protection
|
Power-down protection | |
Reverse connection | ||
Over-temperature protection | ||
Over-voltage protection | ||
Short-circuit protection | ||
IP Grade | IP20 | |
Channel Control Mode | Independent control | |
High Voltage Insulation Between Channels | AC1000V/2min Normal | |
Voltage & Current Test Sampling | Five-core wires connection / Probe | |
Noise | < 76 dB | |
Host Computer Communication Method | based on TCP/IP protocol | |
Test Report Output Method | Excel | |
Server Disk Configuration | >100GB | |
Server Operation System | Windows XP, Windows 7/8/10 | |
Communication Port | LAN | |
Equipment Work Ambient Conditions | ||
Operation Ambient Temperature | 0 ℃ – 40 ℃ | |
Storage Temperature | -10 ℃ – 50 ℃ | |
Operation Ambient Humidity | ≤ 70 % RH (No condensation) | |
Storage Ambient Humidity | ≤ 80 % RH (No condensation) |
Illustrations:
Product Size: 80*45*200 cm (L*W*H)
Software Interfaces
Main Interfaces
List Display
Work Step Setting
Match Conditions Setting
Single Channel Data Analysis
Multiple Channel Data Analysis and Comparison
Test Data Exporting
Device Connection Diagram: