Hybrid Electric Car Ni-MH/Lithium Battery Charge and Discharge Testing Balance Maintenance Tester Analyzer HBT2010
is suitable for capacity testing, charge characteristic testing, data grading and matching, balance charge and discharge maintenance, internal resistance testing of various batteries of Nickel-Metal Hydride, Nickel-Chromium, Lithium, Lead-acid. The isolation detection technology can determine the location of the defective modules without disassembling the battery pack. It can balance charge and discharge the unbalanced battery pack and restore the battery pack to normal balance.
The device is integrated with Battery Temperature Monitoring System, work step switching and charging stop can be realized by setting the temperature to ensure accurate and safe battery testing & maintenance with unattended.
It is widely used in the detection and repair of traction batteries in electric vehicle maintenance and service industries, especially for the detection and maintenance of hybrid batteries composed of 4.8V/7.2V/9.6V/14.4V battery modules. Such as Honda, Toyota, Lexus, Nissan, Ford, Porsche and other hybrid vehicle models.
Applicable Batteries:
Features:
• Each channel is equipped with a dedicated processor to ensure a perfect level of capacity calculation, timing, voltage and current control.
• All channels are under isolated testing, it can directly test the cells of the battery pack.
• Independent heat source channel, temperature control and speed regulation fan.
• The LED light indicates the running status, testing status, matching status, and alarm status.
• Fully compatible with the batteries of Lead-acid, Li-ion, Polymer, Ni-MH, NiCad, and so on.
• Online test between computer and device, the setting and result is particular and plentiful,
• With the work steps of Constant Current Discharge, Constant Power Discharge, Constant Resistance Discharge, Constant Current Charge, Constant Voltage Charge, Constant Current & Voltage Charge, Internal Resistance Test and Idle, etc.
• Work step automatically switching.
• The charge and discharge parameters can be customized.
• The matching can be processed, the test results can be matched according to the customized standard, and it can mark and display on the device.
• Battery anti-reverse connection protection and alarm.
• The recording function of the test process.
• With 3 Y-axis (voltage, current, capacity) and a time axis curve drawing ability, and data report function.
• The color of the test status bar is customized, which makes it easy to check the test status of all devices when the number of tests is large.
• Isolation channel battery temperature monitoring system, work step switching and charging stop can be realized by setting the temperature to ensure accurate and safe battery testing & maintenance with unattended.
Application Cases:
TechnicalSpecification:
Model No.: HBT2010-34 | ||
Input Voltage: | 3-Phase 380V 50Hz/60Hz | |
Input Power: | No-load 100W, full load 7820W | |
Voltage |
Charge Constant Voltage Range: | 2 V – 20 V adjustable |
Discharge Cut-off Voltage Range: | 2 V – 20 V adjustable | |
Tolerance: | ± 0.02 V | |
Current |
Charge Current: | 0.05 A – 10 A Adjustable |
Discharge Current: | 0.05 A – 10 A Adjustable | |
Charge Cut-off Current: | 0.05A – 5 A | |
Tolerance: | ± 0.02 A | |
Power | Max. Output Power (Single Channel) | 230 W |
Data Recording |
Data Recording Conditions |
Time interval |
Voltage interval | ||
Current interval | ||
Charge |
Charge Modes: |
Constant current charge |
Constant voltage charge | ||
Constant current & voltage charge | ||
Charge Cut-off Conditions: | Voltage, Current, Time, Capacity, -△V. Temperature | |
Discharge |
Discharge Modes: |
Constant current discharge |
Constant power discharge | ||
Constant resistance discharge | ||
Discharge Cut-off Conditions: | Voltage, current, time, capacity | |
Cycle | Cycle Index: | 1-5000times |
Protection |
Power-down protection | |
Reverse connection | ||
Over-temperature protection | ||
Over-voltage protection | ||
Short-circuit protection | ||
IP Grade | IP20 | |
Channel Control Mode | Independent control | |
High Voltage Insulation Between Channels | AC1000V/2min Normal | |
Voltage & Current Test Sampling | Four-core wires connection | |
Noise | < 76 dB | |
Host Computer Communication Method | based on TCP/IP protocol | |
Test Report Output Method | Excel | |
Server Disk Configuration | >100GB | |
Server Operation System | Windows XP, Windows 7/8/10 | |
Communication Port | LAN | |
Equipment Work Ambient Conditions | ||
Operation Ambient Temperature | 0 ℃ – 40 ℃ | |
Storage Temperature | -10 ℃ – 50 ℃ | |
Operation Ambient Humidity | ≤ 70 % RH (No condensation) | |
Storage Ambient Humidity | ≤ 80 % RH (No condensation) |
Illustrations:
Produce Size: 70*60*85 CM(L*W*H)
Weight:: 115 kgs
Software Interfaces
Main Interfaces
List Display
Work Step Setting
Match Conditions Setting
Single Channel Data Analysis
Multiple Channel Data Analysis and Comparison
Test Data Exporting
Device Connection Diagram: