Storage Battery Testing and Regeneration Instrument SF100-5
SF100 is a professional battery performance testing instrument integrated with high precision capacity discharge test, ordinary three-stage charge, water-replenishing maintenance charge, pulse repair. It can set the voltage and current of charge and discharge by the user and has the function of auto charge-discharge cycling, The instrument also has the pulse repair function to repair the vulcanization of the battery, so that the battery capacity can be restored to normal levels, which can greatly prolong service life and extending the warranty time.
It’s an essential instrument for battery performance testing & scheduled maintenance to prolong the service life of the batteries.
Applicable Batteries:
6V/8V/12V/16V/18V Lead-acid batteries, recommended capacity:<30 AH
Features:
– Instrument displays by LCD, each index is clear at a glance.
– The parameter setup and parameter switching are set and switched by a “START” switch and a “SET” knob. All parameters(voltage, current, mode) setting have the saving function.
– Intelligent speed fan can run continuously, delay the power-off of the fan, and blow-off the remaining heat.
– Polarity protection, anti-reverse connection, and so on.
– Each circuit is the independent module, no influence each other
– The instrument have simple mode and professional mode for choice to meet the different requirement of the user.
– Data protection startup: If the connection cables disconnected from the battery during the charging and discharging, after reconnecting the cables with the battery, press and hold the “Start” button to continue working.
– Power-off memory function.
Operation Modes:
10 operation modes
Mode Code | Function |
0 | Enquire |
1 | Capacity Test |
2 | Typical Charging |
3 | Discharging→Idle→Charging |
4 | Charging→Idle→Discharging→Idle→Charging |
5 | Discharging→Idle→Charging→Idle→Discharging→Idle→Charging |
6 | Charging→Idle→Discharging→Idle→Charging→Idle→Discharging→Idle→Charging |
7 | Automatic Repair Mode: Charging→Idle→Repair→Idle→Discharging→Idle→Charging |
8 | Pulse Repair Mode |
9 | Charging→Discharging |
Technical Specification:
Model No.: SF100-5/6 | ||||
Items | Parameter | |||
Input Voltage: | AC 220 V± 10% 50 Hz / 60 Hz | |||
Input Power: | No-load: | SF100-5 | SF100-6 | |
70W | 80W | |||
Full-load: | SF100-5 | SF100-6 | ||
750W | 900W | |||
Applicable Battery Types: | 6 V, 12 V, 16 V, 18V Storage Batteries | |||
Functions: | Charge | |||
Discharge | ||||
Auto cycle charge and discharge | ||||
Pulse repair | ||||
Data record and inquire | ||||
Voltage | Max. Charge Voltage: | 23 V | ||
Min. Charge Voltage: | 3.6 V | |||
Amplitude Of Adjustment: | 0.1 V stepping | |||
Charge Voltage Tolerance: | ± 0.5 V | |||
Max. Discharge Cut-off Voltage: | 20 V | |||
Min. Discharge Cut-off Voltage: | 2 V | |||
Amplitude Of Adjustment: | 0.1 V stepping | |||
Discharge Voltage Tolerance: | ± 0.03 V | |||
Current | Charge Current: | 0.5 A – 6 A adjustable | ||
Amplitude Of Adjustment: | 0.1 A stepping | |||
Charge Current Tolerance: | ± 0.1 A | |||
Discharge Current: | 0.5 A – 10 A adjustable | |||
Amplitude Of Adjustment: | 0.1 A stepping | |||
Discharge Current Tolerance: | ± 0.03 A | |||
Charge | Charge Mode: | Constant current & voltage charge | ||
Cut-off Conditions: | When reaching high constant voltage, the system will automatically switch to trickle charge after charging for 3.5 hours or the charging current is less than 0.3A | |||
Discharge | Discharge Mode: | Constant current discharge | ||
Cut-off Conditions: | Voltage | |||
Cycle | Cycle Mode 1 | DSCH → IDLE→CHG | ||
Cycle Mode 2 | CHG→IDLE→DSCH→IDLE→CHG | |||
Cycle Mode 3 | DSCH→IDLE→CHG→IDLE→DSCH→IDLE →CHG | |||
Cycle Mode 4 | CHG→IDLE→DSCH→IDLE→CHG→IDLE →DSCH→IDLE→CHG | |||
Cycle Mode 5 | CHG →IDLE→DSCH | |||
Pulse Repair | Pulse Current: | 0.3 A | ||
Pulse Frequency: | 500 Hz | |||
Time of Single Repair: | 12 HRS | |||
Protection: | Power-down protection | |||
Reverse connection protection | ||||
Over-temperature protection | ||||
Over-voltage protection | ||||
Short-circuit protection | ||||
IP Grade | IP20 | |||
Channel Control Mode | Independent control | |||
High Voltage Insulation Between Channels | AC1000V/2min Normal | |||
Data Display | LCD | |||
Operation Method | Panel | |||
Voltage & Current Test Sampling | Five-core wires connection | |||
Noise | < 76 dB | |||
Upper Computer Communication | None | |||
Communication Port | None | |||
Equipment Work Ambient Conditions | ||||
Operation Ambient Temperature | 0 ℃ – 40 ℃ | |||
Storage Temperature | -10 ℃ – 50 ℃ | |||
Operation Ambient Humidity | ≤ 70 % RH (No condensation) | |||
Storage Ambient Humidity | ≤ 80 % RH (No condensation) |
Illustrations
LCD Interface
Packing Information:
Model No.: | SF100-5 | SF100-6 |
Product Size(L*W*H): | 59.5*40*17 cm | 71*40*17 cm |
Pcs/Ctn: | 1 pcs/ctn | 1 pcs/ctn |
Package Size(L*W*H): | 70.5*50*31 cm | 82.5*50*31 cm |
G.W.: | 17.80 kgs | 18.8 kgs |
N.W.: | 15.80 kgs | 16.8 kgs |